Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10609/147654
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorGoodkin, Olivia-
dc.contributor.authorPemberton, Hugh-
dc.contributor.authorVos, Sjoerd B.-
dc.contributor.authorPrados Carrasco, Ferran-
dc.contributor.authorDas, Ravi K.-
dc.contributor.authorMoggridge, James-
dc.contributor.authorDe Blasi, Bianca-
dc.contributor.authorBartlett, Philippa-
dc.contributor.authorWilliams, Elaine-
dc.contributor.authorCampion, Thomas-
dc.contributor.authorHaider, Lukas-
dc.contributor.authorPearce, Kirsten-
dc.contributor.authorBargallό, Nuria-
dc.contributor.authorSanchez, Esther-
dc.contributor.authorBisdas, Sotirios-
dc.contributor.authorWhite, Mark-
dc.contributor.authorOurselin, Sebastien-
dc.contributor.authorWinston, Gavin-
dc.contributor.authorDuncan, John S-
dc.contributor.authorCardoso, Jorge-
dc.contributor.authorThornton, John S.-
dc.contributor.authorYousry, Tarek-
dc.contributor.authorBarkhof, Frederik-
dc.contributor.otherUniversity College London (UCL)-
dc.contributor.otherUniversitat Oberta de Catalunya (UOC). Estudis d'Informàtica, Multimèdia i Telecomunicació-
dc.contributor.otherMedical University of Vienna-
dc.contributor.otherInstitut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS)-
dc.contributor.otherVU University Medical Centre-
dc.contributor.otherKing’s College London-
dc.contributor.otherQueen's University-
dc.date.accessioned2023-03-13T11:31:02Z-
dc.date.available2023-03-13T11:31:02Z-
dc.date.issued2021-01-02-
dc.identifier.issn1432-1084MIAR
-
dc.identifier.urihttp://hdl.handle.net/10609/147654-
dc.description.abstractObjectives; Hippocampal sclerosis (HS) is a common cause of temporal lobe epilepsy. Neuroradiological practice relies on visual assessment, but quantification of HS imaging biomarkers—hippocampal volume loss and T2 elevation—could improve detection. We tested whether quantitative measures, contextualised with normative data, improve rater accuracy and confidence. Methods; Quantitative reports (QReports) were generated for 43 individuals with epilepsy (mean age ± SD 40.0 ± 14.8 years, 22 men; 15 histologically unilateral HS; 5 bilateral; 23 MR-negative). Normative data was generated from 111 healthy individuals (age 40.0 ± 12.8 years, 52 men). Nine raters with different experience (neuroradiologists, trainees, and image analysts) assessed subjects’ imaging with and without QReports. Raters assigned imaging normal, right, left, or bilateral HS. Confidence was rated on a 5-point scale. Results; Correct designation (normal/abnormal) was high and showed further trend-level improvement with QReports, from 87.5 to 92.5% (p = 0.07, effect size d = 0.69). Largest magnitude improvement (84.5 to 93.8%) was for image analysts (d = 0.87). For bilateral HS, QReports significantly improved overall accuracy, from 74.4 to 91.1% (p = 0.042, d = 0.7). Agreement with the correct diagnosis (kappa) tended to increase from 0.74 (‘fair’) to 0.86 (‘excellent’) with the report (p = 0.06, d = 0.81). Confidence increased when correctly assessing scans with the QReport (p < 0.001, η2 p = 0.945). Conclusions; QReports of HS imaging biomarkers can improve rater accuracy and confidence, particularly in challenging bilateral cases. Improvements were seen across all raters, with large effect sizes, greatest for image analysts. These findings may have positive implications for clinical radiology services and justify further validation in larger groups. Key Points; • Quantification of imaging biomarkers for hippocampal sclerosis—volume loss and raised T2 signal—could improve clinical radiological detection in challenging cases. • Quantitative reports for individual patients, contextualised with normative reference data, improved diagnostic accuracy and confidence in a group of nine raters, in particular for bilateral HS cases. • We present a pre-use clinical validation of an automated imaging assessment tool to assist clinical radiology reporting of hippocampal sclerosis, which improves detection accuracy.en
dc.format.mimetypeapplication/pdf-
dc.language.isoengen
dc.publisherSpringer Nature-
dc.relation.ispartofEuropean Radiology volume, 2021, 31-
dc.relation.ispartofseriesEuropean Radiology;31-
dc.relation.urihttps://doi.org/10.1007/s00330-020-07075-2-
dc.rightsCC BY 4.0-
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.subjectepilepsyen
dc.subjectepilèpsiaca
dc.subjectepilepsiaes
dc.subjecttemporal lobeen
dc.subjectlòbul temporalca
dc.subjectlóbulo temporales
dc.subjecthippocampusen
dc.subjecthipocampca
dc.subjecthipocampoes
dc.subjectbiomarkersen
dc.subjectbiomarcadorsca
dc.subjectbiomarcadoreses
dc.subjectmagnetic resonance imagingen
dc.subjectimatges per ressonància magnèticaca
dc.subjectimagen por resonancia magnéticaes
dc.subject.lcshmagnetic resonance imagingen
dc.titleClinical evaluation of automated quantitative MRI reports for assessment of hippocampal sclerosisen
dc.typeinfo:eu-repo/semantics/article-
dc.subject.lemacimatgeria per ressonància magnèticaca
dc.subject.lcshesResonancia magnética nuclear (Medicina)en
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.doihttps://doi.org/10.1007/s00330-020-07075-2-
dc.gir.idAR/0000008039-
dc.relation.projectIDinfo:eu-repo/grantAgreement/NIHR/EPSRC-
dc.type.versioninfo:eu-repo/semantics/publishedVersion-
Aparece en las colecciones: Articles
Articles cientÍfics

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Clinical_evaluation_of_automated_quantitative_MRI_reports_for_assessment_of_hippocampal_sclerosis.pdf3,7 MBAdobe PDFVista previa
Visualizar/Abrir
Comparte:
Exporta:
Consulta las estadísticas

Los ítems del Repositorio están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.