Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10609/99630
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorArias de la Torre, Jorge-
dc.contributor.authorDomingo Torrell, Laia-
dc.contributor.authorMartínez Cruz, Olga-
dc.contributor.authorRobles Muñoz, Noemí-
dc.contributor.authorPuigdomenech Puig, Elisa María-
dc.contributor.authorPons Cabrafiga, Miquel-
dc.contributor.authorPallisó, Francesc-
dc.contributor.authorMora, Xavier-
dc.contributor.authorEspallargues Carreras, Mireia-
dc.date.accessioned2019-07-22T09:01:34Z-
dc.date.available2019-07-22T09:01:34Z-
dc.date.issued2019-02-21-
dc.identifier.citationArias de la Torre, J., Domingo, L., Martínez, O., Robles Muñoz, N., Puigdomènech, E., Pons Cabrafiga, M., Pallisó, F., Mora, X. & Espallargues, M. (2019). Evaluation of the effectiveness of hip and knee implant models used in Catalonia: A protocol for a prospective registry-based study. Journal of Orthopaedic Surgery and Research, 14(1), 1-8. doi: 10.1186/s13018-019-1087-z-
dc.identifier.issn1749-799XMIAR
-
dc.identifier.urihttp://hdl.handle.net/10609/99630-
dc.description.abstractBackground: Monitoring results regarding the effectiveness of knee and hip arthroplasties may be useful at the clinical, economic and patient level and help reduce the number of prosthesis revisions. In Spain, and specifically in Catalonia, there is currently no systematic monitoring of the different prosthesis models available on the market. Within this context, the aim of the project presented in this protocol is to evaluate the short- and medium-term effectiveness of knee and hip models implanted in Catalonia and to identify where the results could be better or worse than expected. Methods: A prospective observational design will be drawn up based on data from a population-based arthroplasty register for hip and knee replacements that includes data from 53 of the 61 public hospitals in Catalonia. The knee and hip prosthesis models used will be identified and classified according to the type of prosthesis, fixation and, in total hip replacements, the bearing surface. For the data analysis, two methodological approaches will be used sequentially: first, an approach based on a survival analysis, followed by an approach based on standardised revision ratios and funnel plots. Following the analyses, a panel of experts will evaluate the results to identify possible sources of bias. Lastly, those models with results better or worse than expected compared to those from the comparison group will be valued, and strengths and difficulties for routine implementation of this methodology within the Catalan Arthroplasty Register will be identified. Discussion: The study presented in this protocol will allow us to identify the hip and knee prosthesis models whose results might be better or worse than expected. This information could have a potential impact at the patient, orthopaedic surgeon, healthcare manager, decision-making and industry levels, both in the short term and in the medium and long term.en
dc.language.isoeng-
dc.publisherJournal of Orthopaedic Surgery and Research-
dc.relation.urihttps://josr-online.biomedcentral.com/track/pdf/10.1186/s13018-019-1087-z-
dc.rightscc-by-
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/-
dc.subjectOutlier detectionen
dc.subjectArthroplastyen
dc.subjectSurvival analysisen
dc.subjectFunnel ploten
dc.subject.lcshProsthesisen
dc.subject.lcshArthroplastyen
dc.titleEvaluation of the effectiveness of hip and knee implant models used in Catalonia: A protocol for a prospective registry-based study-
dc.typeinfo:eu-repo/semantics/article-
dc.subject.lemacPròtesisca
dc.subject.lemacArtroplàstiaca
dc.subject.lcshesPrótesises
dc.subject.lcshesArtroplastiaes
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.doi10.1186/s13018-019-1087-z-
dc.gir.idAR/0000007019-
dc.type.versioninfo:eu-repo/semantics/publishedVersion-
Aparece en las colecciones: Articles
Articles cientÍfics

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
implant_models_Catalonia.pdf659,25 kBAdobe PDFVista previa
Visualizar/Abrir
Comparte:
Exporta:
Consulta las estadísticas

Los ítems del Repositorio están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.