Citació: Gholami, N., Dehshibi, M.M., Adamatzky, A., Rueda-Toicen, A., Zenil, H., Fazlali, M. & Masip, D. (2020). A novel method for reconstructing CT images in GATE/GEANT4 with application in medical imaging: A complexity analysis approach. Journal of Information Processing, 28, 161-168. doi: 10.2197/ipsjjip.28.161
Resum: For reconstructing CT images in the clinical setting, "effective energy" is usually used instead of the total X-ray spectrum. This approximation causes an accuracy decline. We proposed to quantize the total X-ray spectrum into irregular intervals to preserve accuracy. A phantom consisting of the skull, rib bone, and lung tissues was irradiated with CT configuration in GATE/GEANT4. We applied inverse Radon transform to the obtained Sinogram to construct a Pixel-based Attenuation Matrix (PAM). PAM was then used to weight the calculated Hounsfield unit scale (HU) of each interval's representative energy. Finally, we multiplied the associated normalized photon flux of each interval to the calculated HUs. The performance of the proposed method was evaluated in the course of Complexity and Visual analysis. Entropy measurements, Kolmogorov complexity, and morphological richness were calculated to evaluate the complexity. Quantitative visual criteria (i.e., PSNR, FSIM, SSIM, and MSE) were reported to show the effectiveness of the fuzzy C-means approach in the segmenting task.
Paraules clau: complexitat
imatge del TAC
FCM
GATE/Geant4
unitat Hounsfield
matriu d'atenuació basada en píxels
DOI: 10.2197/ipsjjip.28.161
Tipus de document: info:eu-repo/semantics/article
Versió del document: info:eu-repo/semantics/publishedVersion
Data de publicació: feb-2020
Apareix a les col·leccions:Articles cientÍfics
Articles

Arxius per aquest ítem:
Arxiu Descripció MidaFormat 
Dehshibi_Masip_JIP_A_novel.pdf
  Restricted Access
5,84 MBAdobe PDFVeure/Obrir Demanar una còpia
Comparteix:
Exporta:
Consulta les estadístiques

Els ítems del Repositori es troben protegits per copyright, amb tots els drets reservats, sempre i quan no s’indiqui el contrari.