Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10609/137087
Título : Validity, reliability, and calibration of the physical activity unit 7 item screener (PAU-7S) at population scale
Autoría: Schröder, Helmut
Subirana, Isaac
Wärnberg, Julia
Medrano, María
González Gross, Marcela
Gusi, Narcis
Aznar, Susana
Alcaraz, Pedro E.
González Valeiro, Miguel A.
Serra-Majem, Lluis  
Terrados, Nicolás
Tur, Josep A.
Segú, Marta
Homs, Clara
Alvarez-Garcia, Alicia  
Benavente Marín, Juan C.
Barón López, F. Javier
Labayen, Idoia
Zapico, Augusto G.
Sánchez Gómez, Jesús
Jiménez Zazo, Fabio
Marín Cascales, Elena
Sevilla Sanchez, Marta
Herrera Ramos, Estefanía
Pulgar, Susana
Bibiloni, María del Mar
Sistac Sorigué, Clara
Gómez, Santiago F.
Otros: Universitat Oberta de Catalunya (UOC)
Citación : Schröder, H., Subirana, I., Wärnberg, J. et al. Validity, reliability, and calibration of the physical activity unit 7 item screener (PAU-7S) at population scale. Int J Behav Nutr Phys Act 18, 98 (2021). https://doi.org/10.1186/s12966-021-01169-w
Resumen : Background: Validation of self-reported tools, such as physical activity (PA) questionnaires, is crucial. The aim of this study was to determine test-retest reliability, internal consistency, and the concurrent, construct, and predictive validity of the short semi-quantitative Physical Activity Unit 7 item Screener (PAU-7S), using accelerometry as the reference measurement. The effect of linear calibration on PAU-7S validity was tested. Methods: A randomized sample of 321 healthy children aged 8-16 years (149 boys, 172 girls) from the nationwide representative PASOS study completed the PAU-7S before and after wearing an accelerometer for at least 7 consecutive days. Weight, height, and waist circumference were measured. Cronbach alpha was calculated for internal consistency. Test-retest reliability was determined by intra-class correlation (ICC). Concurrent validity was assessed by ICC and Spearman correlation coefficient between moderate to vigorous PA (MVPA) derived by the PAU-7S and by accelerometer. Concordance between both methods was analyzed by absolute agreement, weighted kappa, and Bland-Altman statistics. Multiple linear regression models were fitted for construct validity and predictive validity was determined by leave-one-out cross-validation. Results: The PAU-7S overestimated MVPA by 18%, compared to accelerometers (106.5 ± 77.0 vs 95.2 ± 33.2 min/day, respectively). A Cronbach alpha of 0.76 showed an acceptable internal consistency of the PAU-7S. Test-retest reliability was good (ICC 0.71 p < 0.001). Spearman correlation and ICC coefficients of MVPA derived by the PAU-7S and accelerometers increased from 0.31 to 0.62 and 0.20 to 0.62, respectively, after calibration of the PAU-7S. Between-methods concordance improved from a weighted kappa of 0.24 to 0.50 after calibration. A slight reduction in ICC, from 0.62 to 0.60, yielded good predictive validity. Multiple linear regression models showed an inverse association of MVPA with standardized body mass index (B - 0.162; p < 0.077) and waist to height ratio (B - 0.010; p < 0.014). All validity dimensions were somewhat stronger in boys compared to girls. Conclusion: The PAU-7S shows a good test-retest reliability and acceptable internal consistency. All dimensions of validity increased from poor/fair to moderate/good after calibration. The PAU-7S is a valid instrument for measuring MVPA in children and adolescents.
Palabras clave : children and adolescents
self-reported physical activity
short PAQ
validation
accelerometry
DOI: https://doi.org/10.1186/s12966-021-01169-w
Tipo de documento: info:eu-repo/semantics/article
Fecha de publicación : 17-jul-2021
Licencia de publicación: http://creativecommons.org/licenses/by/3.0/es/  
Aparece en las colecciones: Articles
Articles cientÍfics

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Validity, reliability, and calibration of the physical activity unit 7 item screener.pdf916,05 kBAdobe PDFVista previa
Visualizar/Abrir