Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10609/137157
Título : Open-access quantitative MRI data of the spinal cord and reproducibility across participants, sites and manufacturers
Autoría: Cohen-Adad, Julien
Alonso-Ortiz, Eva
Abramovic, Mihael
Arneitz, Carina
Atcheson, Nicole
Barlow, Laura
Barry, Robert L.
Barth, Markus
Battiston, Marco  
Büchel, Christian
Budde, Matthew
Callot, Virginie
Combes, Anna J.E.
de Leener, Benjamin
Descoteaux, Maxime
de Sousa, Paulo Loureiro
Dostál, Marek
Doyon, Julien
Dvorak, Adam
Eippert, Falk
Epperson, Karla R.
Epperson, Kevin S.
Freund, Patrick
Finsterbusch, Jürgen
Foias, Alexandru
Fratini, Michela
Fukunaga, Issei
Gandini Wheeler-Kingshott, Claudia A.M.  
Germani, Giancarlo
Gilbert, Guillaume
Giove, Federico
Gros, Charley
Grussu, Francesco  
Hagiwara, Akifumi
Henry, Pierre-Gilles
Horák, Tomás
Hori, Masaaki
Joers, James
Kamiya, Kouhei
Karbasforoushan, Haleh
Kerkovsky, Milos
Khatibi, Ali
Kim, Joo-Won
Kinany, Nawal
Kitzler, Hagen H.
Kolind, Shannon
Kong, Yazhuo
Kudlicka, Petr
Kuntke, Paul
Kurniawan, Nyoman D.
Kusmia, Slawomir
Labounek, René
Laganà, Maria Marcella
Laule, Cornelia
Law, Christine S.
Lenglet, Christophe
Leutritz, Tobias
Liu, Yaou
Llufriu, Sara  
Mackey, Sean
Martínez-Heras, Eloy
Mattera, Loan
Nestrasil, Igor
O'Grady, Kristin P.
Papinutto, Nico
Papp, Daniel
Pareto, Deborah  
Parrish, Todd B.
Pichiecchio, Anna
Prados Carrasco, Ferran  
Rovira, Alex  
Ruitenberg, Marc J.
Samson, Rebecca  
Savini, Giovanni
Seif, Maryam
Seifert, Alan C.
Smith, Alex K.
Smith, Seth A.
Smith, Zachary A.
Solana, Elisabeth  
Suzuki, Y.
Tackley, George
Tinnermann, Alexandra
Valosek, Jan
van de Ville, Dimitri
Yiannakas, Marios  
Weber, Kenneth A.
Weiskopf, Nikolaus
Wise, Richard G.
Wyss, Patrik O.
Xu, Junqian
Otros: Universitat Oberta de Catalunya (UOC)
Universitat Oberta de Catalunya. eHealth Center
Citación : Cohen-Adad, J., Alonso-Ortiz, E., Abramovic, M. et al. Open-access quantitative MRI data of the spinal cord and reproducibility across participants, sites and manufacturers. Sci Data 8, 219 (2021). https://doi.org/10.1038/s41597-021-00941-8
Resumen : In a companion paper by Cohen-Adad et al. we introduce the spine generic quantitative MRI protocol that provides valuable metrics for assessing spinal cord macrostructural and microstructural integrity. This protocol was used to acquire a single subject dataset across 19 centers and a multi-subject dataset across 42 centers (for a total of 260 participants), spanning the three main MRI manufacturers: GE, Philips and Siemens. Both datasets are publicly available via git-annex. Data were analysed using the Spinal Cord Toolbox to produce normative values as well as inter/intra-site and inter/intra-manufacturer statistics. Reproducibility for the spine generic protocol was high across sites and manufacturers, with an average inter-site coefficient of variation of less than 5% for all the metrics. Full documentation and results can be found at https://spine-generic.rtfd.io/. The datasets and analysis pipeline will help pave the way towards accessible and reproducible quantitative MRI in the spinal cord.
Palabras clave : databases
imaging techniques
spinal cord diseases
DOI: https://doi.org/10.1038/s41597-021-00941-8
Tipo de documento: info:eu-repo/semantics/article
Fecha de publicación : 16-ago-2021
Licencia de publicación: http://creativecommons.org/licenses/by/3.0/es/  
Aparece en las colecciones: Articles
Articles cientÍfics

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Open-access quantitative MRI.pdf8,63 MBAdobe PDFVista previa
Visualizar/Abrir