Títol: Generalised boundary shift integral for longitudinal assessment of spinal cord atrophy
Autoria: Prados Carrasco, Ferran  
Moccia, Marcello
Johnson, Aubrey
Yiannakas, Marios  
Grussu, Francesco  
Cardoso, Manuel Jorge
Ciccarelli, Olga  
Ourselin, Sebastien
Barkhof, Frederik  
Gandini Wheeler-Kingshott, Claudia A.M.  
Altres: University College London (UCL)
Università degli Studi di Pavia
King's College London
Universitat Oberta de Catalunya (UOC)
Citació: Prados, F., Moccia, M., Johnson A., Yiannakas M., Grussu, F., Cardoso, M. J., Ciccarelli, O., Ourselin, S., Barkhof, F., Wheeler-Kingshott, C. (2020). Generalised boundary shift integral for longitudinal assessment of spinal cord atrophy. NeuroImage, 209. doi: 10.1016/j.neuroimage.2019.116489
Resum: Spinal cord atrophy measurements obtained from structural magnetic resonance imaging (MRI) are associated with disability in many neurological diseases and serveasin vivobiomarkers of neurodegeneration. Longitudinal spinal cord atrophy rate is commonly determined from the numerical difference between two volumes (basedon 3D surfacefitting) or two cross-sectional areas (CSA, based on 2D edge detection) obtained at different time-points. Being an indirect measure, atrophy rates aresusceptible to variable segmentation errors at the edge of the spinal cord. To overcome those limitations, we developed a new registration-based pipeline thatmeasures atrophy rates directly. We based our approach on the generalised boundary shift integral (GBSI) method, which registers 2 scans and uses a probabilistic XORmask over the edge of the spinal cord, thereby measuring atrophy more accurately than segmentation-based techniques. Using a large cohort of longitudinal spinalcord images (610 subjects with multiple sclerosis from a multi-centre trial and 52 healthy controls), we demonstrated that GBSI is a sensitive, quantitative andobjective measure of longitudinal spinal cord volume change. The GBSI pipeline is repeatable, reproducible, and provides more precise measurements of longitudinalspinal cord atrophy than segmentation-based methods in longitudinal spinal cord atrophy studies.
Paraules clau: Spinal cord atrophy
GBSI Method
DOI: 10.1016/j.neuroimage.2019.116489
Tipus de document: info:eu-repo/semantics/article
Versió del document: info:eu-repo/semantics/publishedVersion
Data de publicació: 1-abr-2020
Llicència de publicació: http://creativecommons.org/licenses/by/4.0/es/  
Apareix a les col·leccions:Articles
Articles cientÍfics

Arxius per aquest ítem:
Arxiu Descripció MidaFormat 
Prados_NeuroImage_Spinal_cord.pdf1,33 MBAdobe PDFThumbnail
Veure/Obrir
Comparteix:
Exporta:
Consulta les estadístiques

Aquest ítem està subjecte a una llicència de Creative Commons Llicència Creative Commons Creative Commons