Empreu aquest identificador per citar o enllaçar aquest ítem: http://hdl.handle.net/10609/143729
Títol: Qualitative and quantitative comparison of hippocampal volumetric software applications: do all roads lead to rome?
Autoria: Mangesius, Stephanie  
Haider, Lukas  
Lenhart, Lukas
Steiger, Ruth
Prados Carrasco, Ferran  
Scherfler, Christoph
Gizewski, Elke R.
Altres: Medical University of Innsbruck
University College London Institute of Neurology
Medical University of Vienna
University College London (UCL)
Universitat Oberta de Catalunya
Citació: Mangesius, S., Haider, L., Lenhart, L., Steiger, R., Prados, F., Scherfler, C. & Gizewski, E.R. (2022). Qualitative and Quantitative Comparison of Hippocampal Volumetric Software Applications: Do All Roads Lead to Rome?. Biomedicines, 10(2), 1-15. doi: 10.3390/biomedicines10020432
Resum: Brain volumetric software is increasingly suggested for clinical routine. The present study quantifies the agreement across different software applications. Ten cases with and ten gender- and age-adjusted healthy controls without hippocampal atrophy (median age: 70; 25-75% range: 64-77 years and 74; 66-78 years) were retrospectively selected from a previously published cohort of Alzheimer's dementia patients and normal ageing controls. Hippocampal volumes were computed based on 3 Tesla T1-MPRAGE-sequences with FreeSurfer (FS), Statistical-Parametric-Mapping (SPM; Neuromorphometrics and Hammers atlases), Geodesic-Information-Flows (GIF), Similarity-and-Truth-Estimation-for-Propagated-Segmentations (STEPS), and Quantib. MTA (medial temporal lobe atrophy) scores were manually rated. Volumetric measures of each individual were compared against the mean of all applications with intraclass correlation coefficients (ICC) and Bland-Altman plots. Comparing against the mean of all methods, moderate to low agreement was present considering categorization of hippocampal volumes into quartiles. ICCs ranged noticeably between applications (left hippocampus (LH): from 0.42 (STEPS) to 0.88 (FS); right hippocampus (RH): from 0.36 (Quantib) to 0.86 (FS). Mean differences between individual methods and the mean of all methods [mm3] were considerable (LH: FS -209, SPM-Neuromorphometrics -820; SPM-Hammers -1474; Quantib -680; GIF 891; STEPS 2218; RH: FS -232, SPM-Neuromorphometrics -745; SPM-Hammers -1547; Quantib -723; GIF 982; STEPS 2188). In this clinically relevant sample size with large spread in data ranging from normal aging to severe atrophy, hippocampal volumes derived by well-accepted applications were quantitatively different. Thus, interchangeable use is not recommended.
Paraules clau: imatge de resonancia magnetica
cervell
software
hipocamp
atrofia
DOI: https://doi.org/10.3390/biomedicines10020432
Tipus de document: info:eu-repo/semantics/article
Versió del document: info:eu-repo/semantics/publishedVersion
Data de publicació: 12-feb-2022
Llicència de publicació: http://creativecommons.org/licenses/by/4.0  
Apareix a les col·leccions:Articles cientÍfics
Articles

Arxius per aquest ítem:
Arxiu Descripció MidaFormat 
biomedicines-10-00432-v2.pdf1,14 MBAdobe PDFThumbnail
Veure/Obrir
Comparteix:
Exporta:
Consulta les estadístiques

Aquest ítem està subjecte a una llicència de Creative Commons Llicència Creative Commons Creative Commons